OpenMinder™: Readings
The following table describes the reading fields available through the API. The asterisk signifies fields that can be calibrated.
Field | Description | Unit | Side |
---|---|---|---|
irrig_adc | Raw pH voltage from the circuit | volts | Irrigation |
irrig_ph_raw | The uncalibrated pH value | pH | Irrigation |
irrig_ph * | The pH value | pH | Irrigation |
runoff_adc | Raw pH voltage from the circuit | volts | Runoff |
runoff_ph_raw | The uncalibrated pH value | pH | Runoff |
runoff_ph * | The pH value | pH | Runoff |
irrig_tips | Number of tips the tipping bucket has recorded | count | Irrigation |
irrig_volume * | The volume of water that has run through the tipping bucket | mL | Irrigation |
runoff_tips | Number of tips the tipping bucket has recorded | count | Runoff |
runoff_volume * | The volume of water that has run through the tipping bucket | millilitres | Runoff |
irrig_ec * | The nutrient value | mS/cm2 | Irrigation |
irrig_ec_raw | The uncalibrated nutrient value | mS/cm2 | Irrigation |
irrig_ectemp | The water temperature | °C | Irrigation |
runoff_ec * | The nutrient value | mS/cm2 | Runoff |
runoff_ec_raw | The uncalibrated nutrient value | mS/cm2 | Runoff |
runoff_ectemp | The water temperature | °C | Runoff |
runoff_ratio | The runoff ratio between the irrigation and runoff side | percentage | Combined |